6/12 Roof Pitch

A 6/12 roof pitch rises 6 inches for every 12 inches of horizontal run, about 26.6° and a 50% slope. Its pitch multiplier is 1.118, so every 100 square feet of footprint becomes about 111.8 square feet of roof surface. PitchCalc labels 6/12 conventional, while OSHA's construction fall-protection standard defines it as a steep roof.

Check your own roof's pitch →

6/12 pitch at a glance

run 12 inrise 6 in
Angle
26.6°
Slope
50%
Pitch multiplier
1.118
Rafter per foot of run
1 ft 1⅜ in
Rise per foot of run
6 in
PitchCalc class
Conventional
OSHA term
Steep roof

How steep is a 6/12 roof?

At 26.6°, a 6/12 roof rises half a foot for every foot of run, which is why its slope is exactly 50%. It is 4° steeper than 5/12 and 3.7° shallower than 7/12, and it sits near the middle of the 4:12 to 9:12 range that GAF says covers most U.S. residential roofs[1]. Over a 12-foot run the roof climbs 6 feet.

The pitch multiplier matters more here than on shallow roofs. A 6/12 surface is 11.8% larger than its footprint, compared with 5.4% at 4/12, so footprint-based material estimates drift further if the multiplier is left out. OSHA's construction fall-protection standard defines a steep roof as one with a slope greater than 4 in 12[2], so 6/12 falls on the steep side of that definition even though PitchCalc's planning label for it is conventional.

What roofing works on a 6/12 pitch?

A 6/12 pitch is above the 2024 IRC minimum slope for every covering this site tracks: asphalt shingles at 2:12, clay and concrete tile at 2½:12, metal roof shingles and wood shingles at 3:12, and slate at 4:12[3]. Because it is above 4:12, asphalt shingles use standard single-layer underlayment instead of the double layer required on low slopes[3].

Clearing a code minimum is not the same as being the right product for a roof. Exposure, fastening, and other requirements in the manufacturer's installation instructions still apply, and the code your jurisdiction has adopted is the version an inspector will check.

6/12 rise and rafter length by run

Rise and sloped rafter length for common horizontal runs, before overhang.

RunRiseRafter length
6 ft3 ft 0 in6 ft 8½ in
8 ft4 ft 0 in8 ft 11⅜ in
10 ft5 ft 0 in11 ft 2⅛ in
12 ft6 ft 0 in13 ft 5 in
14 ft7 ft 0 in15 ft 7⅞ in
16 ft8 ft 0 in17 ft 10⅝ in

A 30 ft × 50 ft footprint (1,500 sq ft) at 6/12 has about 1,677.1 sq ft of sloped roof, or 16.77 squares before waste.

Run your own footprint →

6/12 vs 5/12 and 7/12

6/12 compared with the neighboring pitches
PitchAngleSlopeMultiplier
5/1222.6°41.7%1.083
6/1226.6°50%1.118
7/1230.3°58.3%1.158

6/12 roof pitch FAQ

Common questions about a 6/12 roof.

Is a 6/12 pitch steep?

It depends on the definition. PitchCalc labels 6/12 conventional because it falls within 4/12 to 9/12. OSHA's construction fall-protection standard defines any roof with a slope greater than 4 in 12 as a steep roof, so for OSHA purposes 6/12 counts as steep. Its angle is about 26.6°.

What is the 6/12 pitch multiplier?

The 6/12 pitch multiplier is 1.118, the square root of 1 + (6 ÷ 12)². Use it to turn a footprint into sloped roof area: 1,500 sq ft of footprint at 6/12 is about 1,677.1 sq ft of roof, or 16.77 roofing squares before waste is added.

How long is a rafter on a 6/12 roof?

Multiply the horizontal run by 1.118. A rafter spanning a 12-foot run is about 13 ft 5 in long before overhang, ridge deductions, or cuts. For your own span and overhang, use the rafter calculator.

Sources

Code, safety-standard, and industry claims on this page cite the following.

  1. GAF, Minimum Slope for Shingles — GAF, “Minimum Slope for Shingles: What Contractors Need to Know,” 7 February 2025.
  2. OSHA 29 CFR 1926.500(b) — Occupational Safety and Health Administration, 29 CFR 1926.500, Scope, application, and definitions (construction fall protection): “low-slope roof” is a slope less than or equal to 4 in 12; “steep roof” is a slope greater than 4 in 12. Checked November 16, 2026.
  3. IRC 2024, Chapter 9 — International Code Council, 2024 International Residential Code, Chapter 9 Roof Assemblies, including §R905.2.2 (asphalt shingles: 2:12 minimum; double underlayment 2:12 up to but not including 4:12), §R905.3.2 (clay and concrete tile), §R905.4.2 (metal roof shingles), §R905.6.2 (slate), and §R905.7.2 (wood shingles).