6/12 Roof Pitch
A 6/12 roof pitch rises 6 inches for every 12 inches of horizontal run, about 26.6° and a 50% slope. Its pitch multiplier is 1.118, so every 100 square feet of footprint becomes about 111.8 square feet of roof surface. PitchCalc labels 6/12 conventional, while OSHA's construction fall-protection standard defines it as a steep roof.
6/12 pitch at a glance
- Angle
- 26.6°
- Slope
- 50%
- Pitch multiplier
- 1.118
- Rafter per foot of run
- 1 ft 1⅜ in
- Rise per foot of run
- 6 in
- PitchCalc class
- Conventional
- OSHA term
- Steep roof
How steep is a 6/12 roof?
At 26.6°, a 6/12 roof rises half a foot for every foot of run, which is why its slope is exactly 50%. It is 4° steeper than 5/12 and 3.7° shallower than 7/12, and it sits near the middle of the 4:12 to 9:12 range that GAF says covers most U.S. residential roofs[1]. Over a 12-foot run the roof climbs 6 feet.
The pitch multiplier matters more here than on shallow roofs. A 6/12 surface is 11.8% larger than its footprint, compared with 5.4% at 4/12, so footprint-based material estimates drift further if the multiplier is left out. OSHA's construction fall-protection standard defines a steep roof as one with a slope greater than 4 in 12[2], so 6/12 falls on the steep side of that definition even though PitchCalc's planning label for it is conventional.
What roofing works on a 6/12 pitch?
A 6/12 pitch is above the 2024 IRC minimum slope for every covering this site tracks: asphalt shingles at 2:12, clay and concrete tile at 2½:12, metal roof shingles and wood shingles at 3:12, and slate at 4:12[3]. Because it is above 4:12, asphalt shingles use standard single-layer underlayment instead of the double layer required on low slopes[3].
Clearing a code minimum is not the same as being the right product for a roof. Exposure, fastening, and other requirements in the manufacturer's installation instructions still apply, and the code your jurisdiction has adopted is the version an inspector will check.
For every covering side by side, use the full table. See minimum slopes by roof covering.
6/12 rise and rafter length by run
Rise and sloped rafter length for common horizontal runs, before overhang.
| Run | Rise | Rafter length |
|---|---|---|
| 6 ft | 3 ft 0 in | 6 ft 8½ in |
| 8 ft | 4 ft 0 in | 8 ft 11⅜ in |
| 10 ft | 5 ft 0 in | 11 ft 2⅛ in |
| 12 ft | 6 ft 0 in | 13 ft 5 in |
| 14 ft | 7 ft 0 in | 15 ft 7⅞ in |
| 16 ft | 8 ft 0 in | 17 ft 10⅝ in |
A 30 ft × 50 ft footprint (1,500 sq ft) at 6/12 has about 1,677.1 sq ft of sloped roof, or 16.77 squares before waste.
6/12 roof pitch FAQ
Common questions about a 6/12 roof.
Is a 6/12 pitch steep?
It depends on the definition. PitchCalc labels 6/12 conventional because it falls within 4/12 to 9/12. OSHA's construction fall-protection standard defines any roof with a slope greater than 4 in 12 as a steep roof, so for OSHA purposes 6/12 counts as steep. Its angle is about 26.6°.
What is the 6/12 pitch multiplier?
The 6/12 pitch multiplier is 1.118, the square root of 1 + (6 ÷ 12)². Use it to turn a footprint into sloped roof area: 1,500 sq ft of footprint at 6/12 is about 1,677.1 sq ft of roof, or 16.77 roofing squares before waste is added.
How long is a rafter on a 6/12 roof?
Multiply the horizontal run by 1.118. A rafter spanning a 12-foot run is about 13 ft 5 in long before overhang, ridge deductions, or cuts. For your own span and overhang, use the rafter calculator.
Sources
Code, safety-standard, and industry claims on this page cite the following.
- GAF, Minimum Slope for Shingles — GAF, “Minimum Slope for Shingles: What Contractors Need to Know,” 7 February 2025.
- OSHA 29 CFR 1926.500(b) — Occupational Safety and Health Administration, 29 CFR 1926.500, Scope, application, and definitions (construction fall protection): “low-slope roof” is a slope less than or equal to 4 in 12; “steep roof” is a slope greater than 4 in 12. Checked November 16, 2026.
- IRC 2024, Chapter 9 — International Code Council, 2024 International Residential Code, Chapter 9 Roof Assemblies, including §R905.2.2 (asphalt shingles: 2:12 minimum; double underlayment 2:12 up to but not including 4:12), §R905.3.2 (clay and concrete tile), §R905.4.2 (metal roof shingles), §R905.6.2 (slate), and §R905.7.2 (wood shingles).