Roof Pitch Calculator

Convert rise and run, an angle, or slope % to roof pitch and a multiplier.

MODEL PC-01 · US CUSTOMARY

Measurements stay in this browser.No signup · replace the example with your tape

Convert rise and run

Results update as you type. Nothing is stored on a server.

Measurements stay in your browser
Pitch ratio6 / 1226.6° · ×1.118

Input mode

Example values — replace with your measurements.

in

Vertical distance

in

Horizontal distance · usually 12

Common pitches

run 12 inrise 6 in
Optional rafter overhang
in

Added to run before rafter length

Roof pitch is rise over run, written as X:12 — the inches a roof climbs for every 12 inches of horizontal run. A roof that rises 6 inches over 12 inches of run is a 6:12 pitch, about 26.6° or a 50% slope. To convert any pitch, the angle is arctan(rise ÷ run), the slope percent is rise ÷ run × 100, and the pitch multiplier is √(1 + (rise ÷ run)²), here 1.118. Multiply the horizontal footprint of a single-pitch roof, overhangs included, by that multiplier to get sloped roof area.

Know your house length and width? Start with the Roofing Calculator →

What's new

  • — Added a printable 1/12–24/12 chart with PDF and PNG downloads, a free embed widget, and a rafter math worksheet.
  • — Folded the separate slope calculator into this page; use the Slope % or Angle mode above.
  • — Added a short answer above explaining how pitch converts to degrees, slope percent, and the multiplier.
  • — Cited the 2024 IRC, GAF, and NRCA on minimum roof-covering slopes.

How to calculate roof pitch

  1. Enter a measurement

    Use rise and horizontal run in inches, or switch to Angle or Slope %.

  2. Read the conversion

    Get pitch per 12 inches of run, angle, slope percent, and multiplier.

  3. Use the result

    Copy or print it, or continue to roof area and bundles with your pitch.

Roof pitch conversions

Use this roof slope calculator as a roof angle calculator to convert roof pitch to degrees, slope percent, and a roof pitch multiplier.

Common examples — not your current result
PitchAngleSlopeMultiplier
4/1218.4°33.3%1.054
6/1226.6°50.0%1.118
8/1233.7°66.7%1.202
12/1245.0°100.0%1.414

Have slope percent or degrees instead of X:12? Switch the calculator above to Slope % or Angle mode ↑

View the full roof pitch chart

Publishing a guide or product page? Embed the free pitch converter (ad-free; keep the PitchCalc credit).

Pitch
Vertical rise for every 12 units of horizontal run.
Angle
The roof’s inclination above horizontal, in degrees.
Slope
Rise divided by run, expressed as a percentage.
Multiplier
Converts horizontal projected area to sloped area for one uniformly pitched section.

100% slope means 45°, not a vertical roof. Run is horizontal distance, not the sloped roof length.

Pitch ratio and measurement units

An X:12 pitch states the rise for every 12 units of horizontal run. A 6-inch rise over a 12-inch level run is a 6/12 pitch. The ratio is unitless when rise and run use the same unit. This calculator uses inches for rise, run, overhang, and rafter length, so convert field measurements to inches before entering them.

Convert roof pitch to degrees and percent

Degrees = arctan(rise / run) × 180 / π. Slope percent = rise / run × 100. A plan, digital level, or angle finder may report an angle instead of an X:12 ratio; enter that angle in Angle mode. Small rounding differences are normal when converting between formats.

How the roof pitch multiplier works

Multiplier = √(1 + (rise / run)²). Multiply horizontal projected area by this factor only when the area and pitch describe the same uniformly pitched roof section. Measure dormers, intersecting sections, and irregular outlines separately. Material waste, laps, cuts, openings, and installation requirements are separate from this geometry.

Use the Roof Area Calculator for sloped area. See the calculation methodology for formulas and assumptions.

How to measure roof pitch

How to measure a 6 over 12 roof pitch with a levelA level touches the underside of one rafter at its upper left end. Its upper surface runs horizontally 12 inches to the right. From that point, a vertical measurement rises 6 inches to the rafter underside.Rafter undersideContact12 in run6 inrise
Example: 6 in rise over a level 12 in run = 6/12 pitch. Measure to the rafter underside; the level thickness is not part of either measurement.
  1. From a safely accessible attic, hold a level horizontally with one end against the underside of a rafter.
  2. At the 12-inch mark, measure vertically up to the rafter. That gap is the rise.
  3. Enter that rise with a 12-inch run. For a different measured run, enter both actual measurements in inches.

Do not climb onto a roof just to use this calculator. If access is unsafe, use drawings or a qualified professional.

Measurement checks and limitations

Keep the run level, measure the rise at a right angle, and use the same unit for both. On a simple centered gable, one roof-side run is often half the wall-to-wall span; verify the actual wall-to-ridge geometry. Add overhangs separately. Do not use the full building width as the run for one side, or reverse rise and run.

The rafter result is straight-line geometry, not structural sizing. It does not include ridge, seat, or plumb cuts. Verify dimensions, loads, fastening, and code requirements before ordering or building. Leave direct measurement to a qualified professional if a roof is damaged, wet, icy, unusually steep, or near power lines.

Read the complete roof pitch measurement guide

Minimum slope for roof coverings

Pitch, angle, and percent are geometry. Whether a covering may go on that slope is a code and manufacturer question. The 2024 International Residential Code allows asphalt shingles only on slopes of 2:12 (17-percent slope) or greater and requires double underlayment from 2:12 up to but not including 4:12; at 4:12 and above, standard single-layer underlayment applies[1]. The same chapter sets other covering floors, including 2½:12 for clay and concrete tile, 3:12 for metal roof shingles and wood shingles, and 4:12 for slate[1].

GAF matches that 2:12 asphalt-shingle minimum, treats 2:12 up to but not including 4:12 as low slope needing two layers of roof-deck protection, and notes that most U.S. residential roofs fall between 4:12 and 9:12[2]. The National Roofing Contractors Association describes low-slope membrane roofs as generally 3:12 or less[3]. PitchCalc labels under 2/12 as flat, 2/12 to under 4/12 as low slope, 4/12 through 9/12 as conventional, and above 9/12 as steep—planning shorthand, not a single code definition.

Which calculator fits your job

Measuring the slope is only the first step. This page converts rise and run into pitch, angle, percent, and the pitch multiplier. When the job starts from a building footprint instead, the roof area calculator turns length, width, overhang, and pitch into sloped square footage and pre-waste roofing squares; the square-footage walkthrough shows how to take those measurements from the ground.

Ordering material is a different step. The shingle calculator takes a known sloped area and returns waste-adjusted squares and whole bundles. The roofing calculator runs the same chain end to end from a footprint or a known area when one workflow is easier than three. Use this page when pitch is the question; use the others once the pitch is settled and material is the answer.

Roof pitch calculator FAQ

These answers explain how roof pitch relates to slope, angle, gradient, and multiplier conversions.

How do I calculate roof pitch?

Measure the vertical rise over a 12-inch horizontal run. If the roof rises 6 inches in those 12 inches, the pitch is 6/12. This pitch of the roof calculator also converts that ratio into degrees, percent slope, and a pitch multiplier.

What is a 6/12 roof pitch?

A 6/12 pitch rises 6 inches for every 12 inches of run, about 26.6 degrees or a 50% slope. Rise by run, rafter length, and coverings: 6/12 roof pitch.

How do I convert roof pitch to degrees?

Degrees = arctangent(rise ÷ run) × 180 ÷ π. A 6/12 pitch is arctangent(0.5), which is 26.6 degrees. You can also enter degrees here and get the equivalent X:12 ratio.

What is a pitch multiplier?

The pitch multiplier converts a horizontal footprint into sloped roof area: multiplier = √(1 + (rise ÷ run)²). Multiply the building’s projected area by this factor to estimate actual roof surface.

Is roof pitch the same as roof slope or roof gradient?

They describe the same geometry in different units. Pitch is usually X-in-12, slope is often a percentage, and gradient or angle is degrees. This page keeps all three in sync; switch the calculator to Slope % or Angle mode to start from a percentage or degrees.

What counts as a low, conventional, or steep slope?

This tool labels under 2/12 as flat, 2/12 to under 4/12 as low slope, 4/12 through 9/12 as conventional, and above 9/12 as steep. Asphalt shingles need double underlayment from 2:12 up to but not including 4:12; at 4:12 and above, standard single-layer underlayment applies. Manufacturer and code limits still govern which materials you can install.

What is a 25% slope in degrees?

A 25% slope is about 14.0 degrees: arctangent(0.25) × 180 ÷ π. It is also a 3/12 pitch, because 25% of 12 inches of run is 3 inches of rise.

How do I convert slope percent to an X:12 pitch?

Divide the percent by 100 and multiply by 12. A 40% slope is 0.40 × 12 = 4.8 inches of rise per 12 inches of run, or 4.8:12. Enter the percent in Slope % mode to get the ratio and angle at once.

Sources

Covering-slope claims on this page cite the following. Follow the adopted local code and the product’s installation instructions.

  1. IRC 2024, Chapter 9 — International Code Council, 2024 International Residential Code, Chapter 9 Roof Assemblies, including §R905.2.2 (asphalt shingles: 2:12 minimum; double underlayment 2:12 up to but not including 4:12), §R905.3.2 (clay and concrete tile), §R905.4.2 (metal roof shingles), §R905.6.2 (slate), and §R905.7.2 (wood shingles).
  2. GAF, Minimum Slope for Shingles — GAF, “Minimum Slope for Shingles: What Contractors Need to Know,” 7 February 2025.
  3. NRCA glossary, low-slope roofs — National Roofing Contractors Association, glossary entry “Low-slope roofs.”