3/12 Roof Pitch
A 3/12 roof pitch rises 3 inches for every 12 inches of horizontal run, about 14.0° and a 25% slope. Its pitch multiplier is 1.031, so the sloped roof is about 3.1% larger than its footprint. PitchCalc labels 3/12 a low slope; asphalt shingles are allowed at this pitch but need double underlayment.
3/12 pitch at a glance
- Angle
- 14.0°
- Slope
- 25%
- Pitch multiplier
- 1.031
- Rafter per foot of run
- 1 ft 0⅜ in
- Rise per foot of run
- 3 in
- PitchCalc class
- Low slope
- OSHA term
- Low-slope roof
How steep is a 3/12 roof?
At 14.0°, a 3/12 roof is shallow. It sits one step below 4/12, the bottom of the 4:12 to 9:12 range that GAF says covers most U.S. residential roofs[1], and it is only 4.5° steeper than 2/12, the lowest slope the 2024 IRC allows for asphalt shingles[2]. Over a 12-foot run the roof climbs just 3 feet, and the sloped surface is 3.1% longer than the run beneath it.
PitchCalc labels everything from 2/12 to under 4/12 as low slope. OSHA's construction fall-protection standard uses its own terms and defines a low-slope roof as one with a slope less than or equal to 4 in 12[3], so a 3/12 roof is low-slope under both labels. These are naming conventions for planning and for jobsite safety rules, not ratings of how a roof performs.
What roofing works on a 3/12 pitch?
Asphalt shingles can go on a 3/12 roof, but the 2024 IRC requires two layers of underlayment anywhere from 2:12 up to, but not including, 4:12[2]. GAF treats the same band as low slope that needs two layers of roof-deck protection[1]. At 3/12 you are inside that band, so the double-underlayment rule applies.
3/12 is also exactly the IRC minimum for metal roof shingles and for wood shingles[2], so those products sit at their floor here rather than comfortably above it. Clay and concrete tile have a 2½:12 minimum but carry their own extra underlayment conditions on slopes under 4:12, while slate needs 4:12 and is not allowed at 3/12[2]. The National Roofing Contractors Association describes low-slope membrane roofs as generally 3:12 or less[4], so 3/12 is at the upper edge of where membrane systems are usually discussed. The product's installation instructions and your adopted local code have the final say.
For every covering side by side, use the full table. See minimum slopes by roof covering.
3/12 rise and rafter length by run
Rise and sloped rafter length for common horizontal runs, before overhang.
| Run | Rise | Rafter length |
|---|---|---|
| 6 ft | 1 ft 6 in | 6 ft 2¼ in |
| 8 ft | 2 ft 0 in | 8 ft 3 in |
| 10 ft | 2 ft 6 in | 10 ft 3¾ in |
| 12 ft | 3 ft 0 in | 12 ft 4⅜ in |
| 14 ft | 3 ft 6 in | 14 ft 5⅛ in |
| 16 ft | 4 ft 0 in | 16 ft 5⅞ in |
A 30 ft × 50 ft footprint (1,500 sq ft) at 3/12 has about 1,546.2 sq ft of sloped roof, or 15.46 squares before waste.
3/12 roof pitch FAQ
Common questions about a 3/12 roof.
Can you put shingles on a 3/12 roof?
Yes. The 2024 IRC allows asphalt shingles on slopes of 2:12 or greater, so a 3/12 roof qualifies. Because 3/12 is below 4:12, the code requires double underlayment rather than a single layer. Follow the shingle manufacturer's low-slope installation instructions as well as your local code.
Is a 3/12 pitch considered flat?
No. PitchCalc labels slopes under 2/12 as flat and 2/12 to under 4/12 as low slope, so 3/12 is a low slope. It rises 3 inches per foot of run, about 14.0°, and it is still within the range where asphalt shingles are allowed with double underlayment.
How much does a 3/12 roof rise over 10 feet?
A 3/12 pitch rises 3 inches per foot of horizontal run, so over a 10-foot run it rises 30 inches, or 2 ft 6 in. The sloped length along the roof over that run is about 10 ft 3¾ in, which is the run multiplied by the pitch multiplier of 1.031.
Sources
Code, safety-standard, and industry claims on this page cite the following.
- GAF, Minimum Slope for Shingles — GAF, “Minimum Slope for Shingles: What Contractors Need to Know,” 7 February 2025.
- IRC 2024, Chapter 9 — International Code Council, 2024 International Residential Code, Chapter 9 Roof Assemblies, including §R905.2.2 (asphalt shingles: 2:12 minimum; double underlayment 2:12 up to but not including 4:12), §R905.3.2 (clay and concrete tile), §R905.4.2 (metal roof shingles), §R905.6.2 (slate), and §R905.7.2 (wood shingles).
- OSHA 29 CFR 1926.500(b) — Occupational Safety and Health Administration, 29 CFR 1926.500, Scope, application, and definitions (construction fall protection): “low-slope roof” is a slope less than or equal to 4 in 12; “steep roof” is a slope greater than 4 in 12. Checked November 16, 2026.
- NRCA glossary, low-slope roofs — National Roofing Contractors Association, glossary entry “Low-slope roofs.”