4/12 Roof Pitch
A 4/12 roof pitch rises 4 inches for every 12 inches of horizontal run, about 18.4° and a 33.3% slope. Its pitch multiplier is 1.054, and each foot of run needs about 1 ft 0⅝ in of rafter. 4/12 is where PitchCalc's conventional range begins and where asphalt shingles switch to standard single-layer underlayment.
4/12 pitch at a glance
- Angle
- 18.4°
- Slope
- 33.3%
- Pitch multiplier
- 1.054
- Rafter per foot of run
- 1 ft 0⅝ in
- Rise per foot of run
- 4 in
- PitchCalc class
- Conventional
- OSHA term
- Low-slope roof
How steep is a 4/12 roof?
At 18.4°, 4/12 is 4.4° steeper than 3/12 and 4.2° shallower than 5/12. GAF notes that most U.S. residential roofs fall between 4:12 and 9:12[1], which puts 4/12 at the shallow end of that common band. Across a 12-foot run the roof rises 4 feet, and the sloped surface is 5.4% longer than the run below it.
4/12 sits on a boundary that different labels draw in different places. PitchCalc calls 4/12 through 9/12 conventional, so 4/12 is the first conventional pitch on this site. OSHA's construction fall-protection standard instead defines a low-slope roof as a slope less than or equal to 4 in 12, and a steep roof as anything greater than 4 in 12[2]. Under OSHA's wording a 4/12 roof is still low-slope, and anything steeper, such as 5/12, is a steep roof.
What roofing works on a 4/12 pitch?
For asphalt shingles, 4/12 is the threshold where the 2024 IRC stops requiring double underlayment: at 4:12 and above, a standard single layer applies[3]. Just below the line, two layers are required, so a roof that measures slightly under 4/12 can need different underlayment from one that measures exactly 4/12 even though the two look the same from the ground. Measure carefully when you are close to the threshold.
4/12 is also the IRC minimum for slate[3], so slate is allowed here but has no margin. Metal roof shingles and wood shingles, each with a 3:12 minimum, and clay or concrete tile, with a 2½:12 minimum, are all above their floors at this pitch[3]. The product's installation instructions and the code your jurisdiction has adopted decide what you can actually install.
For every covering side by side, use the full table. See minimum slopes by roof covering.
4/12 rise and rafter length by run
Rise and sloped rafter length for common horizontal runs, before overhang.
| Run | Rise | Rafter length |
|---|---|---|
| 6 ft | 2 ft 0 in | 6 ft 3⅞ in |
| 8 ft | 2 ft 8 in | 8 ft 5¼ in |
| 10 ft | 3 ft 4 in | 10 ft 6½ in |
| 12 ft | 4 ft 0 in | 12 ft 7¾ in |
| 14 ft | 4 ft 8 in | 14 ft 9⅛ in |
| 16 ft | 5 ft 4 in | 16 ft 10⅜ in |
A 30 ft × 50 ft footprint (1,500 sq ft) at 4/12 has about 1,581.1 sq ft of sloped roof, or 15.81 squares before waste.
4/12 roof pitch FAQ
Common questions about a 4/12 roof.
Is a 4/12 pitch low slope or conventional?
It depends on whose definition you use. PitchCalc labels 4/12 through 9/12 as conventional, and asphalt shingles need only single-layer underlayment from 4:12 up. OSHA's construction fall-protection standard defines a low-slope roof as 4 in 12 or less, so for OSHA purposes a 4/12 roof is low-slope.
What is the multiplier for a 4/12 pitch?
The 4/12 pitch multiplier is 1.054, the square root of 1 + (4 ÷ 12)². It converts horizontal area to roof surface: a 1,500 sq ft footprint at 4/12 covers about 1,581.1 sq ft of roof, or 15.81 squares before any waste allowance.
Can slate go on a 4/12 roof?
Yes, but only just. 4/12 is exactly the 2024 IRC minimum slope for slate, so it is allowed at this pitch and not below it. Because there is no margin, confirm the measured pitch before choosing slate, and follow the slate supplier's installation instructions and your local code.
Sources
Code, safety-standard, and industry claims on this page cite the following.
- GAF, Minimum Slope for Shingles — GAF, “Minimum Slope for Shingles: What Contractors Need to Know,” 7 February 2025.
- OSHA 29 CFR 1926.500(b) — Occupational Safety and Health Administration, 29 CFR 1926.500, Scope, application, and definitions (construction fall protection): “low-slope roof” is a slope less than or equal to 4 in 12; “steep roof” is a slope greater than 4 in 12. Checked November 16, 2026.
- IRC 2024, Chapter 9 — International Code Council, 2024 International Residential Code, Chapter 9 Roof Assemblies, including §R905.2.2 (asphalt shingles: 2:12 minimum; double underlayment 2:12 up to but not including 4:12), §R905.3.2 (clay and concrete tile), §R905.4.2 (metal roof shingles), §R905.6.2 (slate), and §R905.7.2 (wood shingles).